QPL CORP (WAS OMNITECH INTERNATIONAL) -- BRAKE PART CLEANER -- 6850-01-158-3928
=====================  Product Identification  =====================

Product ID:BRAKE PART CLEANER
MSDS Date:07/04/1993
FSC:6850
NIIN:01-158-3928
=== Responsible Party ===
Company Name:QPL CORP (WAS OMNITECH INTERNATIONAL)
Address:800 N ACADIA RD
City:THIBODAUX
State:LA
ZIP:70301
Country:US
Info Phone Num:504-394-8440FAX 504-393-7700
Emergency Phone Num:504-446-2003
CAGE:JO788
=== Contractor Identification ===
Company Name:QPL CORP
Address:40 IDLE BAY DR
Box:City:CENTERPORT
State:NY
ZIP:11721-1138
Country:US
Phone:516-754-0371
CAGE:0RHE6
Company Name:QPL CORP (WAS OMNITECH INTERNATIONAL)
Address:800 NORTH ACADIA RD
City:THIBODAUX
State:LA
ZIP:70301
Country:US
Phone:504-449-8440/504-394-8440
CAGE:JO788
Company Name:QPL INC, FORMERLY OMNITECH INTERNATIONAL, INC.
Address:800 N. ACADIA ROAD
Box:City:THIBODAUX
State:LA
ZIP:70301
Country:US
Phone:504-394-8440
CAGE:0AD61
Company Name:UNI-KEM INTERNATIONAL
Address:1001 HARIMAW COURT EAST
Box:City:METAIRIE
State:LA
ZIP:70001
Country:US
Phone:504-835-7600/FAX:504-835-7608
CAGE:4S446

=============  Composition/Information on Ingredients  =============

Ingred Name:METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE) (SARA III)
CAS:71-55-6
RTECS #:KJ2975000
Fraction by Wt: 75%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:350 PPM/450 STEL
ACGIH TLV:350 PPM/450STEL;9293
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ozone Depleting Chemical:1

Ingred Name:PERCHLOROETHYLENE (TETRACHLOROETHYLENE) (SARA III)
CAS:127-18-4
RTECS #:KX3850000
Fraction by Wt: 25%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:100 PPM
ACGIH TLV:25PPM/100,A3 STEL;94
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS

Ingred Name:CARBON DIOXIDE (PROPELLANT)
CAS:124-38-9
RTECS #:FF6400000
Other REC Limits:NONE RECOMMENDED
OSHA PEL:5000 PPM
ACGIH TLV:5000PPM/30000STEL;93

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: MAY CAUSE EYE & SKIN
    IRRITATION. MAY CAUSE RESPIRATORY TRACT IRRITATION. CENTRAL NERVOUS
    SYSTEM DEPRESSANT. LOSS OF CONSCIOUSNESS AND EVEN DEATH CAN OCCUR
    AT HIGH LEVELS OF EXPOSURE. SWALLOWING  MAY CAUSE GI TRACT
    IRRITATION AND LEADTO ASPIRATION OF VOMIT WHICH CAN BE FATAL.
Explanation of Carcinogenicity:NO INGREDIENT IS LISTED AS A CARCINOGEN
    BY NTP, IARC OR OSHA
Effects of Overexposure:INHALED: COUGHING, WHEEZING, SHORTNESS OF
    BREATH, DIZZINESS, DROWSINESS, NAUSEA, VOMITING, HEADACHE. EYES:
    REDNESS, TEARING, BURNING SENSATION. SKIN: RASH, ITCHING, DRYING.
    INGESTED: NAUSEA, VOMITING,  DIZZINESS, DROWSINESS, HEADACHE.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INHALATION: REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE CPR.
    IF BREATHING IS DIFFICULT, GIVE OXYGEN. CALL A PHYSICIAN. EYE:
    FLUSH IMMEDIATELY WITH LARGE AMOUNTS OF WATER FOR 15 MINUTES. GET
    MEDICAL AT TENTION. SKIN: REMOVE CONTAMINATED CLOTHING. WASH WITH
    SOAP AND WATER PROMPTLY. INGESTION: DO NOT INDUCE VOMITING. IF
    CONSCIOUS, GIVE LOTS OF WATER. GET IMMEDIATE MEDICAL ATTENTION.

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:>200F,>93C
Lower Limits:7.5
Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, OR DRY CHEMICAL.
Fire Fighting Procedures:WEAR FIRE FIGHTING PROTECTIVE EQUIPMENT AND A
    FULL FACED SELF CONTAINED BREATHING APPARATUS. COOL FIRE EXPOSED
    CONTAINERS WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:COMBUSTION OR HEAT OF FIRE MAY PRODUCE
    HAZARDOUS DECOMPOSITION PRODUCTS AND VAPORS. EXPOSURE TO FIRE MAY
    CAUSE CAN TO EXPLODE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:ALLOW PROPELLENTS TO BOIL AND EVAPORATE.
    MAINTAIN GOOD VENTILATION. IF LIQUID SPILLS, ABSORB WITH DRY
    ABSORBENT AND PLACE IN A CONTAINER FOR LATER DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN A COOL, DRY, WELL-VENTILATED
    LOCATION, AWAY FROM ANY AREA WHERE THE FIRE HAZARD MAY BE ACUTE.
    KEEP CONTAINERS CLOSED WHEN NOT IN USE.
Other Precautions:READ AND FOLLOW DIRECTIONS ON LABEL. DO NOT REUSE
    CONTAINERS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE NORMALLY REQUIRED. IF ENGINEERING CONTROLS
    FAIL OR NON-ROUTINE USE OR EMERGENCY OCCURS; USE NIOSH/MSHA
    APPROVED RESPIRATOR OR SUPPLIED AIR RESPIRATOR, OR SCBA, AS
    REQUIRED. USE IAW 29 CFR 1910.13 4.
Ventilation:LOCAL EXHAUST RECOMMENDED TO CONTROL VAPORS BELOW 50% OF
    TLV.
Protective Gloves:NITRILE, BUTYL, OR NEOPRENE RECOMMENDED
Eye Protection:USE SAFETY GLASSES
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.APRON AND
    WORK CLOTHING TO MINIMIZE EXPOSURE. EYE WASH STATION & SAFETY
    SHOWER RECOMMENDE
Work Hygienic Practices:WASH THOROUGHLY AFTER USE AND BEFORE EATING,
    SMOKING OR USING TOILET FACILITIES. DO NOT BREATH VAPORS OR MIST.
Supplemental Safety and Health
TARGET ORGANS ARE SKIN, CNS, CVS, AND EYES. VAPORS WILL COLLECT IN LOW
    AREAS.

==================  Physical/Chemical Properties  ==================

HCC:V2
Boiling Pt:B.P. Text:>200F,>93C
Vapor Pres:>1
Spec Gravity:1.3 (WATER=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:AEROSOL PRESSURIZED SPRAY
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:HIGH HEAT, OPEN FLAMES AND OTHER SOURCES
    OF IGNITION
Hazardous Decomposition Products:CARBON MONOXIDE AND CARBON DIOXIDE,
    HYDROGEN CHLORIDE, HYFROFLUORIC ACID FUMES

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
    FEDERAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.