ARCO NATURAL GAS MARKETING INC., SUBS OF ATLANTIC RICHFIELD -- PLANT RESIDUE GAS, MARSH GAS, NATURAL GAS -- -
===================== Product Identification =====================
Product ID:PLANT RESIDUE GAS, MARSH GAS, NATURAL GAS
MSDS Date:03/01/1989
FSC:NIIN:Submitter:N EN
Status Code:A
=== Responsible Party ===
Company Name:ARCO NATURAL GAS MARKETING INC., SUBS OF ATLANTIC
RICHFIELD
Address:1601 BRYAN ST
City:DALLAS
State:TX
ZIP:75201
Country:US
Info Phone Num:214-880-4698
Emergency Phone Num:(800)424-9300
Resp. Party Other MSDS Num.:E-0010
Chemtrec Ind/Phone:(800)424-9300
CAGE:9B771
=== Contractor Identification ===
Company Name:ARCO NATURAL GAS MARKETING INC., SUBS OF ATLANTIC
RICHFIELD
Address:1601 BRYAN ST
Box:City:DALLAS
State:TX
ZIP:75201
Country:US
Phone:214-880-4698
CAGE:9B771
============= Composition/Information on Ingredients =============
Ingred Name:METHANE
CAS:74-82-8
RTECS #:PA1490000
Ingred Name:CARBON DIOXIDE
CAS:124-38-9
RTECS #:FF6400000
> Wt:5.
OSHA PEL:10000 PPM
OSHA STEL:30000 PPM
ACGIH TLV:5000
ACGIH STEL:30000
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:METHANE IS A SIMPLE ASPHYXIANT.
INHALATION: OXYGEN DEFICIENT ATMOSPHERES MAY PRODUCE RAPID
BREATHING, HEADACHE, DIZZINESS, VISUAL DISTURBANCES, MUSCULAR
WEAKNESS, TREMORS,NARCOSIS, UNCONSCIOUSNESS, AN D DEATH, DEPENDING
ON CONCENTRATION AND DURATION OF EXPOSURE. EYE CONTACT: DIRECT
CONTACT WITH LIQUID/PRESSURIZED GAS OR FROST PARTICLES MAY PRODUCE
SEVERE AND POSSIBLY PERMANENT EYE DAMAGE FROM FREEZ E BURNS. SKIN
ABSORPTION: THIS MATERIAL IS NOT EXPECTED TO BE ABSORBED THROUGH
THE SKIN. SKIN IRRITATION: NON IRRITATING, BUT SOLID AND LIQUID
FORMS OF THIS MATERIAL AND PRESSURIZED GAS CAN CAUSE FRE EZE BURNS.
(SYMPTOMS OF OVEREXP)
Effects of Overexposure:HEALTH HAZARDS (CONT): AND LIQUID FORMS OF THIS
MATERIAL AND THE PRESSURIZED GAS CAN CAUSE FREEZE BURNS. SUMMARY
OF CHRONIC HAZARDS AND SPECIAL HEALTH EFFECTS: PERSONNEL WITH
PRE-EXISTING CHRONIC RES PIRATORY DISEASES SHOULD AVOID EXPOSURE TO
THIS MATERIAL.
Medical Cond Aggravated by Exposure:PERSONNEL WITH PRE-EXISTING CHRONIC
RESPIRATORY DISEASES SHOULD AVOID EXPOSURE TO THIS MATERIAL.
======================= First Aid Measures =======================
First Aid:INHAL: IMMED REMOVE FROM CONTAMD AREA TO FRESH AIR FOR RESP
DISTRESS GIVE AIR OXYG &/OR ADMIN CPR. PATIENTS SHOULD BE KEPT
QUIET & WARM UNTIL MED CARE IS OBTAINED. EYE CONTACT: RINSE IMMED
WITH H*2O. REMOVE CONTACT LENSES THEN FLUSH EYES WITH H*2O FOR
10-15 MIN. IF IRRIT OR DISCOMFORT PERSISTS CALL FOR MED ATTN. SKIN
CNTCT: FROZEN TISS SHOULD BE FLOODED OR SOAKED WITH WARM
H*2O(105'-115'F). DO NOT USE HOT H*2O. CRYOGENIC BURNS WHICH
RESULT IN BLISTERING OR DEEPER TISS FREEZING SHOULD BE PROMPTLY
SEEN BY A MD. INGEST: RINSE MOUTH WITH H*2O DRINK 1-2 GLASSES OF
H*2O OR MILK. DO NOT INDUCE VOMIT UNLESS DIRECT BY MED PERSONNEL.
===================== Fire Fighting Measures =====================
Flash Point:=-187.2C, -305.F
ESTIMATED
Autoignition Temp:=498.9C, 930.F
Autoignition Temp Text:ESTIM
Lower Limits:5.0 APROX
Upper Limits:15.0 APROX
Extinguishing Media:DRY CHEMICAL, CO2, HALOGENATED EXTINGUISHING AGENT
Fire Fighting Procedures:GAS FIRES SHOULD NOT BE EXTINGUISHED UNLESS
THE GAS FLOW CAN BE STOPPED IMMEDIATELY. SHUT OFF GAS SOURCE &
ALLOW THE FIRE TO BURN ITSELF OUT. IF THE SOURCE CAN'T BE SHUT OFF
IMMEDIATELY, ALL EQUIP AND SURFACES EXPOSED TO THE FIRE SHOULD BE
COOLED WITH H*2O TO PREVENT OVERHEATING, FLASH-BACKS, OR
(ECOLOGICAL INFO)
Unusual Fire/Explosion Hazard:THIS GAS RELEASES FLAMM VAPORS AT WELL
BELOW AMBIENT TEMPS & READILY FORMS FLAMM MIXTURES W/ AIR. EXPOSED
TO AN IGNITION SOURCE, IT WILL BURN IN THE OPEN OR BE EXPLOSIVE IN
CONFINED SPACES. VAPORS MAY TRAVEL LONG DISTANCES TO A POINT OF
IGNITION, & THEN FLASH BACK. ALKANE/CHLORINE GAS MIXTURES HAVE
PRODUCED EXPLOSIONS.
================== Accidental Release Measures ==================
Spill Release Procedures:ELIMINATE ALL POTENTIAL SOURCES OF IGNITION.
EVACUATE ALL NON-ESSENTIAL PERSONNEL TO AN AREA UPWIND (AT LEAST
1/2 MILE IN ALL DIRECTIONS IF TANKS OR TANK CARS ARE INVOLVED IN
FIRE). STOP SOURCE OF REL EASE WITH NON-SPARK TOOLS BEFORE PUTTING
OUT ANY FIRE. VENT ENCLOSED AREA TO PREVENT FORMATION OF FLAMMABLE
OR OXYGEN-DEFICNT ATMOSPHERE. WATER SPRAY MAY BE USED TO REDUCE
VAPORS. (OTHER PRECAUTIONS)
====================== Handling and Storage ======================
Handling and Storage Precautions:HANDLING: IF UPON INITIAL RECEIPT
INSPECTION A CYLINDER IS FOUND TO BE IN POOR OPERATING CONDITION,
CONT THE SUPPLIER. THE MOST COMMON HAZARD IS LEAKAGE DUE TO FAULTY
PRESSURE CONTROL REGULATORS. LARG E PRESSURE BUILD-UP CAN RESULT IN
EXPLOSIVE DECOMPRESSION AT THE CYLINDER HEAD CAUSING (OTHER INFO)
Other Precautions:SPILL RELEASE PROC (CONT): LIQUID SPILLS WILL
VAPORIZE FORMING COLD DENSE VAPOR CLOUDS THAT DON'T READILY
DISPERSE. AVOID VAPOR CLOUD EVEN WITH PROPER RESPIRATORY EQUIPMENT.
WASTE DISPOSAL (CONT): O R DISPOSED OF BY BURNING IN A PROPERLY
DESIGNED FLARE OR INCINERATOR. VENTING OF THE GASES TO THE AT M
SHOULD BE AVOIDED.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:FOR EXCESSIVE GAS CONCENTRATIONS, USE ONLY
NIOSH-APPROV, SELF CONTAINED BREATHING APPARATUS. PERSONNEL SHOULD
NOT ENTERAREAS WHERE THE ATMOSPHERE IS BELOW 19.5 VOL % OXYGEN
WITHOUT SPECIAL PROCEDURES / EQUIPMENT. RESPIRATOR USE SHOULD
COMPLY WITH OSHA 29 CFR 1910.134 OR EQUIVALENT.
Ventilation:LOCAL EXHAUST & GENERAL VENT MAY BOTH BE ESSENTIAL TO
PREVENT ACCUM OF EXPLOSIVE MIXTURES. IF MECHANICAL VENT IS USED,
ELECTRICAL EQUIP MUST MEET NEC RQMNTS.
Protective Gloves:INSULATED, IMPERVIOUS PLASTIC OR NEOPRENE-COATED
CANVAS GLOVES
Eye Protection:USE CHEMICAL TYPE GOGGLES (ANSI APPROVED - ) AND FACE
SHIELD (SUPP S & H)
Other Protective Equipment:EMERGENCY EYEWASH FOUNTAINS AND SAFETY
SHOWERS FOR FIRST AID TREATMENT OF POTENTIAL FREEZE BURNS SHOULD BE
AVAILABLE IN THE VICINITY OF ANY SIGNIFICANT EXPOSURE FROM
COMPRESSED GAS RELEASE.
Work Hygienic Practices:PREVENT POTENTIAL SKIN CONTACT WITH COLD LIQUID
/ SOLID / VAPORS. USE INSUL, IMPERV PLASTIC OR NEOPRENE-COATED
CANVAS GLOVES & PROT GEAR (APRON, FACE SHIELD, ETC.) TO PROTECT
HANDS AND OTHER SKIN AREAS
Supplemental Safety and Health
EYE PROT (CONT): WHEN HANDLING LIQUIFIED GASSES. SAFETY GLASSES (ANSI
APPROVED - ) AND/OR FACE SHIELD ARE RECOMMENDED WHEN HANDLING
HIGH-PRESSURE CYLINDERS AND PIPING SYSTEMS AND WHENEVER VAPORS A RE
DISCHARGED.
================== Physical/Chemical Properties ==================
Boiling Pt:=-161.1C, -258.F
B.P. Text:APPROXIMATE
Melt/Freeze Pt:=-182.2C, -296.F
M.P/F.P Text:APPROXIMATE
Vapor Pres:NO DATA AVAILABLE
Vapor Density:0.5 APPROX
Spec Gravity:< 0.30 @ 39.2F
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS, TASTELESS, ODORLESS GAS. (ODOR IS
INADEQUATE WARNING)
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
OXIDIZING AGENTS SUCH AS OXYGEN, CHLORINE, FLUORINE/FLUORIDE COMPOUNDS,
BROMINE & METAL CATALYSTS.
Stability Condition to Avoid:HEAT, SPARKS AND OPEN FLAMES.
Hazardous Decomposition Products:INCOMPLETE COMBUSTION MAY PRODUCE
CARBON MONOXIDE & OTHER HARMFUL SUBSTANCES.
=================== Toxicological Information ===================
Toxicological Information:N/P. HANDLING & STORAGE PREC (CONT): THE
CYLINDER TO ROCKET LIKE A MISSILE. USE PRESSURE-REDUCING REGULATOR
WHEN CONNECTING TO LOWER PRESSURE PIPING SYSTEMS. PREVENT
ENTRAPMENT OF LIQUID IN CLOSED SY STEMS. USE CHECK VALVE TO PREVENT
BACK-FLOW INTO STORAGE CONTAINER. CHAIN CYLINDER WHEN NOT IN USE.
GENERAL COMMENTS: STORE & USE GAS CONTAIN ONLY IN WELL-VENT AREAS.
STORAGE AREAS SHOULD NOT EXCEED 100F & SHOULD BE PROTECTED FROM
DAMPNESS, SALT & CORROSIVE CHEMICALS. CYLINDER STORAGE SHOULD BE
SEGREGATED FROM OXIDIZERS SUCH AS OXYGEN, CHLORINE, ETC. & AWAY FRM
HEAVY TRAFFIC AREAS TO PREVENT KNOC KING OVER OR DAMAGE (ECOLOGICAL
INFO)
===================== Ecological Information =====================
Ecological:N/P. FIRE FIGHT PROC (CONT): EXPLOSIONS. CONTROL FIRE UNTIL
GAS SUPPLY CAN BE SHUT OFF. FIREMEN MUST USE PROPER PROTECTIVE
EQUIPMENT INCLUDING RESPIRATORY APPARATUS TO PROTECT AGAINST
HAZARDOUS COMBU STION PRODUCT / OXYGEN DEFICIENCIES. TOX INFO
(CONT): OF FALLING OBJECTS. AVOID DRAGGING, ROLLING, OR SLIDING
CYLINDERS. VALVE CAPS SHOULD REMAIN ON CYLINDERS NOT CONNECTED FOR
USE. SEPARATE FULL CON TAINERS FROM EMPTY ONES. ODOR IS NOT AN
ADEQUATE WARNING OF POTENTIALLY HAZARDOUS CONCENTRATIONS IN AIR.
FOR AN EXPLANATION OF OCCUPATIONAL EXPOSURE LIMITS REFER TO THE
DEFINITION OF "SIMPLE ASPHYXIAN T" PRESENTED IN THE ACGIH (TRANS
INFO)
==================== Disposal Considerations ====================
Waste Disposal Methods:RELEASES ARE EXPECTED TO CAUSE ONLY LOCALIZED
NON-PERSISTANT ENVIRONMENTAL DAMAGE. WASTE MIXT CONT THESE GASES
SHOULD NOT BE ALLOWED TO ENTER DRAINS OR SEWERS WHERE THERE IS
DANGER OF THEIR VAP BEING IGNITED. WHEN IT BECOMES NECESSARY TO
DISPOSE OF THESE GASES, IT IS PREF TO DO SO AS A VAP THESE GAS ES
MAY BE USED AS AN AUXILIARY FUEL (OTHER PRECS)
=================== MSDS Transport Information ===================
Transport Information:DOT HAZARDOUS MATERIALS PROPER SHIPPING NAME:
METHANE. DOT HAZARD CLASS: FLAMMABLE GAS. UN/NA ID NO: UN 1971.
ECOLOGICAL INFO (CONT): TLV BOOKLET. RELEASES OF THESE GASSES MAY
CAUSE FLAMMABLE ATMOS PHERE WITH EXPLOSION POTENTIAL. THESE
ATMOSPHERES MAY ALSO BE OXYGEN DEFICIENT. DO NOT ENTER SUCH AREAS /
CONFINED SPACESWITHOUT IMPLEMENTING SPECIAL SAFETY PROCEDURES,
INCLUDING MONITORING FOR OXYGEN DEFICIENCY AND FLAMMABLES. THE
INFORMATION AND CONCLUSIONS HEREIN REFLRCT NORMAL OPERATING
CONDITIONS AND MAY BE FROM SOURCES OTHER THAN DIRECT TEST DATA ON
THE MIXTURE ITSELF.
===================== Regulatory Information =====================
SARA Title III Information:N/P. OTHER INFO (CONT): POINT INTENSIFIES
PRESSURE AND RAPID DIFFUSION HAZARD. MAY CAUSE FROSTBITE OR FREEZE
BURNS! AVOID EXPOSURE TO LIQUID OR CRYOGENIC GAS VAPOR.
SUPPLEMENTAL: INDUSTRY EXPERIENCE HAS SHOWN THAT THIS MATERIAL MAY
CONTAIN SMALL AMOUNTS OF RADON, A NATURALLY OCCURING RADIOACTIVE
GAS, AND ITS PARTICULATE DECAY PRODUCTS, SOME OF WHICH MAY BE
RETAINED IN PROCESS EQUIPMENT. GAMMA RA DIATION ABOVE BACKGROUND
LEVELS, EMITTED FROM SHORT HALF-LIFE DECAY PRODUCTS, MAY BE
DETECTED EXTERNALLY AT THAT EQUIPMENT DURING OPERATIONS BUT WILL
DECAY TO BACKGROUND LEVELS WITHIN 4 HOURS AFTER CE SSATION OF FLOW.
(FED REGS)
Federal Regulatory Information:N/P. SARA III (CONT): EQUIPMENT
EMITTING GAMMA RADIATION SHOULD BE PRESUMED TO BE INTERNALLY
CONTAMINATED WITH LONGER-LIFE DECAY PRODUCTS THAT EMIT ALPHA
RADIATION, WHICH MAY BE A HAZARD IF INHALED. IF YOUR ASSESSMENT
INDICATES THE PRESENCE OF GAMMA RADIATION, EMPLOYEE EXPOSURE
POTENTIAL SHOULD BE MINIMIZED BY LIMITING ACCESS NEAR THAT
EQUIPMENT. PRIOR TO MAINTENANCE ON THOSE EQUIPMENT INTERNALS , STOP
FLOW AND ALLOW A 4 HOUR DELAY PRIOR TO OPENING. MAINTENANCE
PERSONNEL SHOULD WEAR APPROPRIATE PROTECTIVE EQUIPMENT TO PREVENT
SKIN CONTAMINATION OR INHALATION OF ANY RESIDUE CONTAINING ALPHA
RADIATION.
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.